REASONS WHY AN IP PAGING SYSTEM IS ESSENTIAL FOR MODERN BUSINESSES

Reasons Why an IP Paging System is Essential for Modern Businesses

Reasons Why an IP Paging System is Essential for Modern Businesses

Blog Article

Network PA System for tool to large tasks



Intro


The XC-9000 system is a fully electronic network PA system based upon the TCP/IP method. By leveraging the TCP/IP protocol, the system ensures the right and efficient transmission of all information packets. Not just can it utilize existing computer system networks, such as LANs or the Internet, to send broadcast signals, however also it can additionally be released on a specialized broadcasting network.


A single-server system can sustain up to 3000 terminals and enables for web server cascading. There are no constraints on the concurrent program channels, attaining true complete electronic broadcasting.


System Qualities



Versatile PA System Design


The PA system style is easy, consisting of service monitoring software application, network microphones, network amplifiers, network speakers, and other devices.All devices is linked by means of the TCP/IP intranet procedure, allowing for flexible arrangement and simple monitoring of the system, with free control over program web content, network gadgets, and regions via the network.


Ip Pa SystemIp Paging Microphone
Comprehensive Audio Monitoring


The audio monitoring software application includes integrated functions for developing program strategies, adaptable zoning, and pre-scheduled broadcasts.It supports 24-hour programs, allowing for changing settings during all the time


Versatile Sound Source Assistance


The system supports numerous forms of audio sources for sending out alerts like live speech and BGM playback. Sound resources can come from digital musical applications, CD/DVD gamers, microphones, and so on. Additionally, the system provides diverse features of supporting different broadcasting attributes such as set up broadcasting, zoned broadcasting, and emergency broadcasting.


Smoke Alarm System Integration


The system has a smoke alarm function and can be incorporated right into an emergency alarm system. When the alarm central device gets the disconcerting signals, the cord will transmit the signal to gadgets, which activates the XC-9000, sending signals to speakers


Users might choose to preset settings to activate full-area or zoned alarms in emergency situations. The alarm voices can be found in multiple types and could be modified dealing with requirements. For instance, customers can change language settings, upload and edit their audio resources according to exact demands, such as intruding alarm systems, emergency alarm or air aid alarms, and so on





Emergency Alarm System Combination


The system has a smoke alarm function and can be integrated right into a smoke alarm system. When the alarm system main system gets the alarming signals, the cord will certainly send the signal to gadgets, which activates the XC-9000, sending signals to speakers


Individuals might select to preset settings to activate full-area or zoned alarm systems in emergencies. The alarm voices can be found in multiple types and can be edited dealing with demands. For instance, users can alter language settings, upload and edit their audio sources according to specific requirements, such as intruding alarms, smoke alarm or air aid alarms, and so on





Application Control for System Procedures


The system enables mobile app login and usage, permitting users to initiate broadcasts and other procedures to accredited terminals via the server software program, ensuring a convenient and structured experience.


Integrated SIP Compatibility


The system not just allows SIP phones to log in, but likewise can be connected to third-party SIP web server or IPPBX, which establishes a totally incorporated and suitable communication system with smooth combination right into existing systems.


Open SDK


When large project like wise park happens, the system provides an open SDK incorporated into third-party application systems - IP Paging Microphone


System Infrastructure



Key Functions


Set up Playback


The system is able to instantly transmit according to the scheduled jobs as long as customers post the audio declare each time duration of the day to the web server and develop a playback schedule.


Zone Broadcasting


The system can randomly split a couple of network gadgets into various zones to play specified audio programs or send out statements to any marked area. The volume of each gadget can be from another location changed.


Real-time Broadcasting


The system can transmit and record radio programs or other outside audio resources in real-time, and at the same time transmitted them in sync.


Smoke Alarm Integration


The system can be incorporated with the fire alarm system for control. When a smoke alarm signal is activated, it automatically triggers the emergency situation broadcast function and click for info sustains adjacent floor alarm systems. It also enables for hand-operated emergency broadcasting by clicking a solitary switch.


SIP Phone Integration


The system can be integrated with SIP web servers, permitting live speech of voice broadcasting using SIP phones to send news anytime and anywhere.


CCTV Combination


The electronic devices such as IP POE Audio speakers adopts the international basic ONVIF protocol, which allows their voices to be broadcast by means of VMS systems. The terminals can also be incorporated with CCTV systems for integrated program.


Key Products



Audio Monitoring Software Program XC-9000


B/S style, supports cross-platform applications.
Covers standard broadcasting system operates, allowing for dividers monitoring.
Unified management of terminals within the system, checking out job condition, and set volume modification, etc.
Sustains building multi-level web server designs, deploying monitoring according to user geographical areas.
Supplies SDK development plans for secondary advancement and integration with various other system platforms.


Network Paging Console XC-9038N


Power: DC12V/1.5 A.
Show: 4-inch touchscreen, resolution 480 * 480.
Communication Methods: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Frequency Reaction: 100Hz~ 16KHz.
Running Temperature level: 0~ 45 ℃.
Dimensions: 144 * 144 * 34.1 mm.


Network Paging Console XC-9037N


Power Supply: DC12V/1.5 A.
Display: 4-inch touchscreen, resolution 480 * 480.
Communication Procedures: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Frequency Response: 100Hz~ 16KHz.
Operating Temperature: 0~ 45 ℃.
Dimensions: 144 * 144 * 34.1 mm.


Network Horn Audio Speaker GEN-6391A03


Power Supply: DC24V/2.7 A or POE.
Interaction Method: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Ratio: > 80dB.
Frequency Reaction: 100Hz~ 18KHz.
Intercom: Sustained, Built-in Microphone.
Operating Temperature level: -20~ 50 ℃.
Measurements: 283.1 * Look At This 224.3 * 269mm.


Network Ceiling Speaker GEN-6211A03


Power Supply: DC 24V/1A or POE.
Interaction Procedures: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Proportion: > 80dB.
Frequency Reaction: 100Hz~ 18KHz.
Running Temperature level: -20 to 50 ° C.
Dimensions: φ213 x 165mm.


Network Wall Mount Audio Speaker GEN-6011A03


Power Supply: DC24V/1A or POE.
Interaction Protocol: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Ratio: > 80dB.
Frequency Reaction: 100Hz~ 18KHz.
Running Temperature level: -20~ 50 ℃.
Dimensions: 193x151.5 x292mm.


Network Column Speaker GEN-6191A03




Power Supply: DC24V/1A or POE.
Communication Method: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 90dB.
Frequency Action: 45Hz~ 18KHz.
Operating Temperature: -10~ 55 ℃.
Measurements: 296x140x130mm.


Network Sound Bridge GEN-3101A01


Power Supply: POE.
Interaction Protocol: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 85dB.
Frequency Feedback: 50Hz~ 20KHz.
Operating Temperature level: -10~ 55 ℃.
Measurements: 126x66x27mm.


Network Digital Amplifier XC-9508P


Power Supply: AC100V~ 240V, 50/60Hz.
Power: 130W, 260W, 360W, 500W.
Communication Protocol: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Regularity Reaction: 60Hz~ 18KHz.
Running Temperature level: -10~ 50 ℃.
Dimensions: 440x300x44mm.


Area Mixing Digital Amplifier NBS-2301


Power Supply : AIR CONDITIONING 220V, 50Hz.
Power : 130W , 260W , 360W , 550W , 700W.
Interaction Protocol : HTTP, TCP/IP, UDP, ARP, ICMP, IGMP.
Signal-to-Noise Proportion :.
Mic Input 01: ≥ 65dB,.
Mic Input 02/03: ≥ 80dB,.
Aux Input 01/02: ≥ 82dB.
Frequency Feedback :.
Mic Input 01: 80Hz~ 14kHz.
Mic Input 02/03: 60Hz~ 16kHz.
Aux Input 01/02: 60Hz~ 16kHz.
Running Temperature level :.
10 ℃~ +50 ℃ (14 ℉~ 122 ℉)
Dimensions : 483x430x88mm.


IP Interface Unit NAC-5003


Power Supply: AC100V~ 240V, 50/60Hz.
Interaction Procedure: TCP/IP, UDP.
User interfaces: 1 Ethernet port, 32 alarm inputs, 8 alarm system results.
Operating Temperature level: -10~ 50 ℃.
Measurements: 483x259x44mm.


Remedy For School





Versatile Zoning Broadcast:


The fully network terminals can understand adaptable zoning options, enabling relaying notifications to specific terminals or various zones ( tools).


College Bell System:


It supplies school bell system at the beginning/ending of the course - IP Speaker. Several situations can be developed, including various arranged broadcast jobs according to summer/winter timetable


Smoke Alarm Assimilation


It supports integration with fire alarm systems, allowing emergency alarm signals to be integrated into the PA system.


Classroom Sound Amplification


Terminals support daily applications in classroom scenes. They can be connected to projectors or interactive whiteboard for audio boosting.


Ip Paging SystemSpon Communications

Smart Street Lamp/Security Post



Support SIP Procedure:


Integrated SIP procedure for seamless combination with network interaction systems.


VMS Operatings Systems Assimilation:


Integrated ONVIF procedure for combination with VMS platforms.


Third-Party Assimilation:


Built in HTTP API for integration with 3rd party systems.


Voice Alarm System Activating:


Built in alarm input user interface for activating voice alarms with video cameras.


Service For Hotel



Area Control by Floor:


The system provides complete network setups, separating areas relying upon various floors and control over each area separately.


Smoke Alarm Assimilation:


The system can be integrated with smoke alarm system, enabling combination of fire alarm signals into the broadcasting system.


Scheduled Broadcasting:


It sustains programmable set up broadcasting, enabling adaptable setups according to numerous requirements.


Emergency situation Broadcasting:


It supports emergency situation broadcasting for the whole area, allowing one-click emergency situation interaction.


Solution For Factory



Zone Broadcasting:


It enables relaying to any kind of zone, guaranteeing no disturbance in between different areas.


Alarm system Triggering:


Terminals have various sort of interfaces, enabling to trigger alarm systems when gotten in touch with video cameras.


All Network Instruments:


Implementation of fully network gadgets substantially reduces the problem of operating such as examining gadgets on unsafe websites, and thus protecting individuals and residential property.


The implementation of all network devices greatly minimizes the difficulty of operation and maintenance monitoring


Integrated SIP Phones:


The system can be incorporated with SIP phone and program notifications utilizing SIP phones at any moment and anywhere. Two-way sound talkback in between SIP phones and IP POE Speakers makes it easy for checking tools resting in workplace or various other work environments.


The XC-9000 system is a completely digital network PA system based on the TCP/IP protocol. By leveraging the TCP/IP method, the system makes certain the proper and reliable transmission of all information packages. The system sustains numerous kinds of audio sources for sending out web notifications like live speech and BGM playback. In enhancement, the system provides diverse functions of supporting different broadcasting attributes such as scheduled broadcasting, zoned broadcasting, and emergency situation broadcasting.


The system can be integrated with the fire alarm system for control.

Report this page